Welcome to vwodis.com.Please click the advertisement below to increase the traffic of our website before reading the article.Thank you!
For your download rights, please register as a member and pay.
When you have finished payment, the download link will be invalid or there is no response when you click download, please contact the customer service of the right scroll bar immediately!
Current Location:Home>Benz>【诊断】VAS5054A PassThru Driver for Xentry PassThru on Windows 10 x64

【诊断】VAS5054A PassThru Driver for Xentry PassThru on Windows 10 x64

Free your eyes, put on your headphones and listen!

Xentry PassThru needs to be installed on Windows x64 to support new models, such as Euro5/6, W205, W213, W222 … However, VAS5054A didn’t work on 64bits as passthru. There was 64bits device driver for VAS5054A but there was no PassThru driver working on 64bits. This is a 64bit device drivers along with a patched PassThru API files. It works on Windows 10 x64. Xentry recognizes it and works with W205 (confirmed), etc.

【诊断】VAS5054A PassThru Driver for Xentry PassThru on Windows 10 x64

WARNING: Use it on your own risk, only for test purpose.

Update (11/2021):

This driver runs on Windows 11 x64 with Xentry 2021.9 and DTS Monaco 8.16 (tested).
Create C:\Temp directory (as noted in *.reg). Without it, the passthru driver may not work properly.

Update (9/2021):

Xentry includes new EDIC PDU API. You can try it but you still need to install the device driver and SAE J2534 API. Attached file v5 includes two more files (Softing_VAS5504A_PassThru_11_28_026.reg, Softing_VAS5054A_PassThru_for_DTS_Monaco.reg).

API 1.20.042 (attached here) : All work (Xentry, Vediamo 4.2.2, DTS Monaco 8.16)
API 11.28.026 (included in Xentry 6/2021) : Only Xentry works.
API 11.26.122 (included in DTS Monaco 8.16) : None work.

To switch to API 1.20.042, double click on Softing_VAS5504A_PassThru_1_20_042.reg
To switch to API 11.28.026, double click on Softing_VAS5504A_PassThru_11_28_026.reg
To use as a J2534 in DTS Monaco, double click on Softing_VAS5054A_PassThru_for_DTS_Monaco.reg

If you install DTS Monaco 8.16, it updates the device driver to v5.1.0.5 (7/13/2018) from v4.3.0.4 (3/1/2016). The new driver also works well. You can switch them back/forth in the windows control panel.

DTS Monaco recognize VAS5054A as not only a native device but also a J2534 PassThru device. To run as a J2534, I had to fix a bug, i.e., double click on Softing_VAS5054A_PassThru_for_DTS_Monaco.reg. Disable or stop “Bus trace” function. It makes monaco.exe lag a lot. (Below photo: it’s recognized as a native device)

【诊断】VAS5054A PassThru Driver for Xentry PassThru on Windows 10 x64

— original post —

What you need:

(1) VAS5054A hardware.
(2) VAS5054A EDIC_PDU_API 1.20.4x driver installation file. You can find it somewhere in this forum (see below).
(3) (option) New firmware. The firmware included here is version 1.20.41 for better compatibility, not 1.20.42.
(4) Softing_VAS5054A_PassThru_Driver_x64_v5.zip (attached here)
(5) 64bit Windows 10
(6) (option) DC 12V 1A power adapter, 2 jumper wires to connect VAS5054 to the temporary power.

Pre Installation:

(1) Install Xentry PassThru and all patches.
(2) Install EDIC_PDU_API 1_20_42 driver (or EDIC_PDU_API 1_20_41). It’s to install .NET framework or VC++ redistribution files.

EDIC_PDU_API driver installs .NET framework, VC++ files, some EDIC DLLs on /Windows/System32 or SysWow64. Other files will be overwritten by the following manual installation. If you don’t know where to find it, one version is (here) or there.

Installation:

(1) Copy “Program Files (x86)\Softing\*” to your HDD “C:\Program Files (x86)\Softing\*”
(2) Copy “Program Data\D-PDU API” to your HDD “C:\Program Data\D-PDU API”.
(3) Double click on “Softing_VAS5054A_PassThru_1_20_042.reg” and install it.
(4) Make a shortcut of “C:\Program Files (x86)\Softing\SAEJ2534-1\SftngCM.exe” on Desktop.
(5) Right click on “C:\Program Files (x86)\Softing\EdicDriver\win7\softingedic7_ntamd64.inf” and install.
(6) Connect the VAS5054A adapter using an USB cable to the labtop.
(7) Connect the VAS5054A to either a OBD2 port or a temporary power(pin 4 or 5 to ground, pin 16 to 12V DC).
(8) Check Control Panel if there is “Devices Manager/Softing Vehicle Interface/VAS5054”. If not, you are doing something wrong.
(9) Make a shortcut of “C:\Program Files (x86)\Softing\EdicDriver\EDICConfig.exe” on Desktop.
(10) Make a shortcut of “C:\Program Files (x86)\Mercedes-Benz\Xentry\bin\PDU\PassThru\ConfigTools\PDUConfigMan.exe on Desktop.

Post Installation:

(1) Connect the VAS5054a to a temporary power(12V DC adapter) or ODB-2 port of your vehicle.
(2) Make a “C:\Temp” directory if not exists. This is to save log files. If not exists, SftingCM.exe will cause error when doing test.
(3) Right click on “SftngCM.exe shortcut” on Desktop and run as administrator.
(4) Choose “VAS5054A” and type the serial number (maybe 0821xxxxx).
(5) Select “Test” and click on “Start Test”.
– RED dot : PC <-> VAS5054A does not communicate. Something wrong on your driver.
– YELLOW dot : PC <-> VAS5054A communicates.
– GREEN dot : PC <-> VAS5054A <-> Vehicle communicates.
(6) Run “PDUConfigMan.exe shortcut” on Desktop and test it. (Newer version of SftngCM.exe included in Xentry). Both shoud work.
(7) If you want to use a newer version of EDIC_PDU-API which is now included in Xentry, open the registry “Softing_VAS5504A_PassThru_11_28_026.reg” (attached below). Search “EDIC_D_PDU_API_11_28_026”. Open “C:\Program Files (x86)\Mercedes-Benz\Xentry\bin\PDU\pdu_api_root_passthru.xml” and search “EDIC_D_PDU_API_*********”. Make the string match (edit *.reg, not *.xml). Save it. Double click on the registry file and add it to Windows registry.
(8) If you want to roll back to EDIC_PDU_API_1_20_42, just double click on the “Softing_VAS5504A_PassThru_1_20_042.reg”.

Tip:

(1) “.NET Framework 2.0/3.0/3.5” needs to be installed if not installed automatically. You can install it by selecting on “Control Panel/Programs and Features/Turn Windows features on or off/.NET Framework 3.5(includes .NET 2.0 and 3.0)”. You also need to install VC++ redistributions if not done yet. (MSVCR100.dll, mfc100.dll, … errors)

(2) Temporary power to VAS5054A for test purpose : Ground to either pin 4 or 5, 12V DC to pin 16.

(3) You can upgrade the EDICDriver in “Program Files (x86)\Softing\EDICDriver” if you have newer version. Update the device driver on control panel.

(4) If you installed newer version EDIC_PDU_API driver than 1.20.42, edit the *.reg and change the number 1_20_42 to your number (for example, “EDIC_D_PDU_API_1_20_042” to “EDIC_D_PDU_API_1_20_0XX“). After editing, double click on it and install it again.

(5) If your device has different serial number but SftngCM.exe doesn’t allow the change, edit the *.reg file with text editor, double click on it and install it again.

【诊断】VAS5054A PassThru Driver for Xentry PassThru on Windows 10 x64

 

 

Download permission
View
  • $
    Download for free
    Download after comment
    Download after login
  • {{attr.name}}:
Your current level is
Login for free downloadLogin Your account has been temporarily suspended and cannot be operated! Download after commentComment Download after paying points please firstLogin You have run out of downloads ( times) please come back tomorrow orUpgrade Membership Download after paying pointsPay Now Download after paying pointsPay Now Your current user level is not allowed to downloadUpgrade Membership
You have obtained download permission You can download resources every daytimes, remaining todaytimes left today
Purchase Statement:
1.Virtual products, once purchased, do not accept any form of refund! If you cannot accept the above agreement, please do not place an order!
2.Virtual products, remote guidance is not accepted! If you cannot accept the above agreement, please do not place an order!
3.All the resources of this site come from the network. Please contact the administrator if your rights and interests are infringed. We will review and delete them at the first time in Email:admin@vwodis.com The resources on the site are used for personal study or test research by netizens. Without the permission of the original copyright author, they are not allowed to be used in any commercial way! Please delete within 24 hours of downloading!

To TAReward
{{data.count}} people in total
The person is Reward
BenzBenz Refitting

【教程】梅赛德斯奔驰204关闭行车测试,屏蔽助力流量阀

2021-10-20 5:16:13

BenzBenz SoftwareXentry OpenShel

【软件】PACK XENTRY PASSTHRU 03.2021 + KEYGEN

2021-11-11 10:27:14

Important statements

The resources of this site are all from the network. Please contact the administrator if your rights are violated,QQ296520384 We will audit and delete them at the first time. The resources on the site are used for personal study or test research by netizens. Without the permission of the original copyright author, they are not allowed to be used in any commercial way! Please delete within 24 hours of downloading!


If you encounterpaycandownWe recommend upgradingSuper Lifetime VIP。All resources of the whole stationAll resources of super permanent members can be downloaded”。A small part of resources in this station are usedRAR compression,To prevent the compression software from not supporting the RAR format,7zDecompress. It is recommended to download7-zip,zip、rarDecompress. It is recommended to downloadWinRAR

0 comment A文章作者 M管理员
    No Comments Yet. Be the first to share what you think
Profile
Cart
Check-in
Message Message
Search